FORTNIGHTLY BOATSHOP PHOTO LOG



















Injector Performance










Return to Photo Log INDEX Page
















INJECTOR PERFORMANCE



















Standard Sizes    Dimensions in inches

Size  (G)     A         B         C          D        E        F     
  00   3/8   4 1/4      2        1 3/4    2 1/8  1 1/4    4 1/2
AA  1/2   5 7/8    2 3/8    2 3/8    2 5/8   1 1/4    5 1/8
BB  3/4   7 1/8    2 3/4    2 7/8   3 1/8    1 5/8     5 3/4









Other Sizes
Please note that we also have larger sizes of  Penberthy Injectors,
available on Special Order:
1",  1 1/4",  1 1/2",  2",  and 2 1/2"















Delivery (gallons per hour) with 12 psig water
                  pressure, water at 74 degrees F.

Size  (G)       Steam Pressure (psig)
                    80       100     120     140     160      200      250
  00   3/8"    80         95     100     115     115      110      105
AA  1/2"    180      210    225      255     255      245      230
BB  3/4"    350      405    440      490     490      475      445









Delivery capacities shown are maximum amount injector can pump at steam pressures indicated.  If flow exceeds amounts shown, due to excessive water supply pressure, vale in water supply line can be regulated to provide correct flow.















Suction Lift Operation  (gph at various suction lifts in feet)

Size  (G)  Vertical                Steam Pressures    (psig)
                Lift (ft.)       40       60       80       100       120       140
00   3/8"       3             60      70        80        75         65         55
                      8            50       65       75        70          61        n/a
AA  1/2"       3           150     175     180       165        155      150
                      8          142     165      157      145        135       n/a
BB  3/4"       3           300     350      350      310        295      280
                      8          290     300      300      270        250      230












Suction lifts to 20 feet are possible without
excessive reduction
in delivery (gph).
Please request data















Delivery capacities are reduced if injectors are required to handle water of higher than normal (74 degrees F) temperature.
When operating with a 3 fi lift at the limiting temperature for a given steam pressure, capacities are reduced approximately as follows:

  Water temp:  90 F   100 F   110 F   120 F
Capacity
  Reduction:    10%    12%     15%    20%

























Move to other Injector Pages
Just CLICK on the page.
UNDERSTANDING INJECTORS
INSTALLATION AND OPERATION
INJECTOR PERFORMANCE
INJECTOR REPAIR PARTS
INJECTOR PRICES




















Return to Photo Log INDEX Page